1-1 PG-05 Appearance

1-2 Explanations of the Terminals of PG-05 Card

Terminals Explanation

VP

Output voltage of encoder: +5V

±5% 200mA

DCM

Common point of the power supply and the signal

A1,
B1,
Z1,

A1

B1
Z1

The input signal of encoder (select output type of the encoder
from FJP1).
The power supply can be single-phase or 2-phase. It can be
up to 500KP/Sec (max.).

A2,
B2,

A2

B2

Pulse (hand wheel and PLC) input (select input type from
FJP4).
The power supply can be single-phase or 2-phase. It can be
up to 500KP/Sec (max.).

AO,
BO,
ZO,

AO

BO
ZO

The output signal of encoder can set the dividing frequency by
using parameter 10-20.
The Max. output of Line drive is 50mA.

1-3 Wiring Examples

Wiring Diagram 1

MPG

FWD
REV
MI1
MI2
MI3
MI4

MI6

MI5

DCM

24V

FWD/STOP

REV/STOP

Multi-step2
Multi-step3
Multi-step4

Digital common

R/L1

S/L2

T/L3

Non-Fuse breaker

NFB

R

S

T

+1 +2/B1 B2

U/T1

V/T2

W/T3

M

3~

Braking Resistor(Option)

Motor

M

u

lt

i-f

u

n

ct

io

n

inp
u

t

te

rm

in

a

ls

F

a

ct

or

y D

e

fa

ul

t

Jumper

Reset

E.F.

-

U

W

V

VP

DCM

A1
A1
B1
B1
Z1
Z1

PG

VP

DCM

A2
A2

B2
B2

Multi-step1

Incremental encoder

Line driver

Line driver

Main circuit (power) terminals

Control circuit terminals

Shielded leads & Cable

10-08

10-12

Hand wheel

AO

BO

ZO

AO

BO

ZO

Wiring Diagram 2

FWD
REV
Mi1
Mi2
Mi3
Mi4

Mi6

Mi5

DCM

24V

FWD/STOP

REV/STOP

Multi-step2
Multi-step3
Multi-step4

Digital common

R/L1

S/L2

T/L3

Non-Fuse breaker

NFB

R

S

T

+1 +2/B1 B2

U/T1

V/T2

W/T3

M

3~

Braking Resistor(Option)

Motor

M

u

lti-

fu

nc
tio

n i

n

pu
t t

e

rm

in

al

s

Fa
c

to

ry

De

fa

u

lt

Jumper

Reset

E.F.

-

U

W

V

VP

DCM

A1

A1

B1
B1
Z1

Z1

PG

DCM

A2
A2

B2
B2

Multi-step1

Incremental encoder

Line driver

Main circuit (power) terminals

Control circuit terminals

Shielded leads & Cable

EH-PLC

Y0
Y0
Y1
Y1

Y0
Y0
Y1
Y1

Phase difference

90

o

COM

AO

BO

ZO

AO

BO

ZO

1-4 Wiring Notes

1. Using the shielded wire to prevent interference, and do not line up in

parallel with circuits of AC200V or above.

2. Recommended wire size: 0.21~0.81mm

2

(AWG24~AWG18).

3. Wire length (It is inversely proportional with signal frequency).

The Output Types

of the Encoder

Max. Wire

Length

Wire Gauge

Voltage 50m

Open Collector

50m

1.25mm

2

(AWG18) or above

Line Driver

300m

Complementary 70m

1.25mm

2

(AWG18) or above

1-5 Installation

For 1-5HP

For 7.5 HP and above

Step 1: Insert 3 PCB supports into control board.

Step 2: Press the PG card on the control board to be fixed to tighten the 3

screws with a torque of 4-6kgf-cm. If the PG card is not fixed on
the control board, it may cause screw idle running and cannot turn
the screw into supports.

1-6 The Corresponding Output Types of Encoder

Output Types of the

Encoder

FJP1 FJP2

V

o

lt

age

O/P

0V

VCC

oc

TP

oc

TP

Open

Collector

O/P

0V

VCC

oc

TP

oc

TP

Line

Driver

Q

Q

oc

TP

oc

TP

Compl

ement

ary

O/P

0V

VCC

oc

TP

oc

TP

Advertising