1.
Cut end of cable at angle to aid in piercing
grommet. Leave additional cable for
expansion loop. See page 4 for multiple
cable installation tips.
4.
Insert banding guide into expediter and
snap into place.
2.
Insert cable into expediter. If mounted on
bottom or side of pipe, punch out weep
hole.
3.
Slide expediter toward pipe and route
cable through support base entry.
7.
Terminate cable with appropriate PETK
termination kit. Refer to PETK installation
instructions.
8.
Push excess cable back through
expediter. Tighten cap securely. Tape
cable expansion loop to pipe.
5.
Mount expediter to pipe using pipe band.
Do not band over cable.
6.
Cut off end of cable.
9.
Mount junction box base on expediter. Make
sure to align slots to properly orient junction
box base. Tighten nut with Terminator-LN-
Tool. If mounting horizontally, threaded
gland holes must face downward.
Terminator
TM
ZP-R-XP
INSTALLATION PROCEDURES