Product data sheets – Dacor EF42NBSS User Manual

Page 20

Advertising
background image

18

Base Grille Water Filtration System (Water Filter)

Model WF-LC400V/LC400V Capacity 400 Gallons (1514 Liters)

This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the

indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water

leaving the system, as specified in ANSI/NSF 42/53.

Substance Reduction

Aesthetic Effects

NSF Reduction

Requirements

Average

Influent

Influent Challenge

Concentration

Maximum

Effluent

Average

Effluent

Minimum %

Reduction

Average %

Reduction

Chlorine Taste/Odor

Particulate Class 1*

≥50%

≥85%

2.1 mg/L

5,366,667/mL

2.0 mg/L ± 10%

At least 10,000

particles/mL

0.06 mg/L

4,100/mL**

0.05 mg/L

2,300/mL

97.1%

99.3%

97.6%

99.9%

Contaminant

Reduction

NSF Reduction

Requirements

Average

Influent

Influent Challenge

Concentration

Maximum

Effluent

Average

Effluent

Minimum %

Reduction

Average %

Reduction

Lead: @ pH 6.5

Lead: @ pH 8.5

0.01mg/L

0.01mg/L

0.152 mg/L†

0.143 mg/L†

0.15 mg/L ± 10%

0.15 mg/L ± 10%

0.001 mg/L

0.001 mg/L

0.001 mg/L

0.001 mg/L

99.34%

99.30%

99.34%

99.30%

Mercury: @ pH 6.5

Mercury: @ pH 8.5

0.002 mg/L

0.002 mg/L

0.0061 mg/L

0.0057 mg/L

0.006 mg/L ± 10%

0.0058 mg/L ± 10%

0.0004 mg/L

0.0008 mg/L

0.0003 mg/L

0.00051 mg/L

93.5%

85.8%

96.7%

91.2%

Benzene

0.005 mg/L

0.0162 mg/L

0.015 ± 10%

0.0005 mg/L

0.001 mg/L

96.3%

96.3%

p-dichlorobenzene

0.075 mg/L

0.220 mg/L

0.225 ± 10%

0.0005 mg/L

0.0005 mg/L

99.7%

99.7%

Toxaphene

0.003 mg/L

0.014 mg/L

0.015 ± 10%

0.0014 mg/L

0.001 mg/L

90%

92.96%

Atrazine

0.003 mg/L

0.0086 mg/L

0.009 mg/L ± 10%

0.0005 mg/L

0.0005 mg/L

94.25%

94.25%

2, 4-D

0.07 mg/L

0.197 mg/L

0.210 ± 10%

0.058 mg/L

0.0137 mg/L

70.6%

93.06%

Asbestos

99%

26 x 107

107 to 108 fibers/L††

0.18 x 107 mg/L 0.18 x 107 mg/L 99.93%

99.93%

Cysts‡

Turbidity

99.95%

0.5 NTU

111,000/mL

11.00 NTU

50,000/L min.

11 ± 1 NTU

1 mg/L

0.40 NTU

1 mg/L

0.35 NTU

99.99%

96.4%

99.99%

96.8%

Product Data Sheets

* Class I particle size: >0.5 to <1 um

** Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.

† These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.

†† Fibers greater than 10 um in length

‡ Based on the use of Cryptosporidium parvum oocysts

® NSF is a registered trademark of NSF International.

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F

(17.2°C).

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

30 - 120 psi (207 - 827 kPa)

Water Temperature

33° - 100°F (0.6° - 37.8°C)

Service Flow Rate

0.5 GPM (1.89 L/min.) @ 60 psi.

Tested and certified by NSF International against ANSI/NSF Standard 42 for

the reduction of Chlorine Taste and Odor, Particulate Class I*; and against

ANSI/NSF Standard 53 for the reduction of Lead, Mercury, Atrazine, Benzene,

Toxaphene, p-dichlorobenzene, 2, 4-D, Cysts, Turbidity and Asbestos.

It is essential that operational, maintenance, and filter

„

replacement requirements be carried out for the product to

perform as advertised.
The filter monitor system measures the amount of water that

„

passes through the filter and alerts you to replace the filter.

When 90% of the filter’s rated life is used, the filter indicator

light changes from green to yellow. When 100% of the filter’s

rated life is used, the filter indicator light changes from yellow

to red, and it is recommended that you replace the filter. Use

replacement cartridge AFF5. See www.everythingdacor.com.
The product is for cold water use only.

„

Advertising