Installation, Warning – Desa RCP80 User Manual

Page 6

Advertising
background image

6

099684

4. Open propane supply valve on propane tank(s) slowly.

Note:

If not opened

slowly, excess-flow check valve on propane tank will stop gas flow. If this
happens, close propane supply valve and open again slowly.

INSTALLATION

3. Connect hose to the inlet connector. Tighten firmly using a wrench.

IMPORTANT:

Use extra hose or piping if needed. Install extra hose or piping

between hose/regulator assembly and propane tank. You must use the regula-
tor supplied with heater even if propane tank has one.

Figure 2 - Regulator With Vent Pointing Down

Continued

Figure 3 - Hose and Inlet Connector

HIGH

LOW

OFF

INDICATOR

Hose

Inlet Connector

POL Fitting

Hose

Regulator

Vent
(pointing down)

Supply Valve

1. Provide propane supply system (see Propane Supply, page 5).
2. Connect POL fitting on hose/regulator assembly to propane tank(s). Turn POL

fitting counterclockwise into threads on tank. Tighten firmly using a wrench.

IMPORTANT:

Tighten regulator with vent pointing down. Pointing vent

down protects regulator from weather damage.

Propane
Tank

WARNING

Test all gas piping and connections for leaks after installa-
tion or servicing. Correct all leaks at once.

WARNING

Review and understand the warnings in the Safety Informa-
tion section, pages 2 and 3. They are needed to safely oper-
ate this heater. Follow all local codes when using this heater.

Advertising
This manual is related to the following products: