Welltech Dialogic SS7 Protocols ISUP User Manual

Page 124

Advertising
background image

Section 8 Non-Primitive Interface

124

Bit Number

Mnemonic

Description

10

ISPF_RPT_UERR

If set to 1, unexpected messages, unexpected
parameters and formatting errors in messages from the
user application are reported. Refer to

Section

:

8.20

Software Event Indication on page 162

.

(ISPe_PAR_FMT_ERR, ISPe_PAR_UNEXPECTED,
ISPe_MSG_UNRECOG, ISPe_FMT_ERR,
ISPe_WRONG_CID, and
ISPe_UMSG_UNEXPECTED) for further information.

11

ISPF_PC_SIZE

If set to 1, the size of the point code used is determined
at run-time for messages received from the MTP. (The
label format is indicated in the id field of the
MTP_TRANSFER_IND).

If the option is not set, the point code size of a message
received from the MTP is determined by the setting of
the ISPF_24PC module option.

Note: currently this option may only be used when
using 16-bit point codes (i.e. when ISPX1GOP_16PC is
set).

12

ISPF_16CID

If set to 1, the most significant bit of the call reference
will no longer be automatically set by the ISUP module
to indicate outgoing calls, instead, the most significant
bit now forms part of the actual circuit id.

If set to 0 and up to a maximum of 32768 circuits are
configured, the most significant bit of the call reference
will be automatically set by the ISUP module to indicate
outgoing calls. (This is backwards compatible with
earlier versions of ISUP).
If more than 32768 circuits
are configured, the most significant bit of the call
reference will not indicate an outgoing call but instead it
is part of an actual circuit id.

13 ISPF_1ST_RESUM

E

If set to 1, this will enable a ISP_CGSC_IND message
(0x070c) to be sent on receipt of the first MTP-
RESUME message.

14 – 15

Reserved

Reserved for future use – set to zero.

module_id

The module id for the partner ISUP module. (The contents of this field are

only used when the ISPF_DUAL bit is set in the options field).

mngt_id

The module id for the management module. This is the module to which all

event and error indications and signaling point status indications are sent. It
is also the default module id for the per-circuit group mngt_id when not

specified separately in the circuit group configuration message.

user_id

The default module id for the application module used when the per-circuit

group user_id is not specified in the circuit group configuration message.

mtp_id

The default module id for the MTP module used when the per-circuit group
mtp_id is not specified in the circuit group configuration message.

Advertising