Westermo DDW-226 User Manual

Page 6

Advertising
background image

6

6642-22402

Ratings

Power

(20 – 48) VDC; 330 mA

Ambient temperature

–40ºC ≤ Ta ≤ +70ºC

Ingress protection (IP)

IP40

Maximum surface temperature

135ºC (temperatur class T4)

Safety Control Drawing

Degree of protection

IP40

Ambient temperature

–40°C to +70°C

Installation spacing

Minimum 25 mm above / below
Minimum 10 mm left / right

Direction relative this unit!

Position

Direction*/

descripton

Input/Output values

1

In/Out / TD+

U = ± 1 V (4μV/s)
I = ± 20 mA
Data rate:
10/100 Mbit/s

2

In/Out / TD–

3

In/Out / RD+

4

Not connected

5

Not connected

6

In/Out / RD–

7

Not connected

8

Not connected

Shield

PE

* Galvanically isolated via signal transformers and capaci-

tively isolated to GND/PE through a 2kV 1000pF

capacitor.

See user manual for proven transient protection.

Position

Direction*/

descripton

Input values

1

In / +Voltage A

U

in

= (10 – 60) VDC

I

in

= 420 mA @ 16 VDC

P

In

= Max 7 W

2

In / +Voltage B

3

In / Common

4

In / Common

* See section Type tests and environmental conditions in this user manual

for proven transient protection.

Position

Direction*/

descripton

Input/Output values

1

In/Out / SHDSL

U = ± 15 Vpk
I = ± 25 mA
Data rate up to
15,3 Mbit/s

2

In/Out / SHDSL

* Galvanically isolated via signal transformer and capaci-

tively isolated to signal ground through a 1,5 kV 220 pF

capacitor.

See user manual for proven transient protection.