fig.

2.95”

5.1”

15.67”

0.86”

Long

screws

1.5”

Wood

screws

8.3”

5.9”

15.98”-FHWC3055L
23.86”-FHWC3655L

Ceiling

Wall

Dimension

A

(see table)

Desired range hood distance above a
36” high cook top

Ceiling height

8 Feet

9 Feet

10 Feet *

1

A*

2

A*

2

A*

2

26”*

3

27-5/16”

27”*

3

28-5/16”

28-5/16”

28”*

3

29-5/16”

29-5/16”

29-5/16”

29”*

3

30-5/16”*

4

30-5/16”

30-5/16”

30”*

3

31-5/16”*

4

31-5/16”

31-5/16”

31”*

3

32-5/16”*

4

32-5/16”

32-5/16”

32”*

3

33-5/16”*

4

33-5/16”

33-5/16”

33”

34-5/16”

34-5/16”

34”

35-5/16”

35-5/16”

35”

36-5/16”

36-5/16”

*

1

: with 10’ Extension chimney kit FHW10X55LS

(14) (not supplied). Please call Frigidaire at
1.800.944.9044 to order this kit.
*

2

: “

Dimension A

” in the chart represents the height

from cook top to where the bottom screw mounting
holes would be located.
*

3

: Recommended mounting height

*

4

: Recirculation Kit cannot be installed.

Step 2:
• Install the range hood (1) either with wood screws

or long screws, depending on the wall type:

Wall type

Required screws

Wood

4 wood screws (11)

Brick/Concrete

4 long screws (8)

Electrical connections

Step 4:
• Loosen the 2 short screws from the junction box

(fig. ).

• Connect the incoming positive, neutral and

ground cables to the respective terminals. The
ground cable is already pre-assembled onto the
junction box to provide grounding (fig. ).

• Insert 2 screws (8 or 11) in the top location, but

do not fully insert the screws (fig. ). Mount the
range hood (1) to the wall and tighten the screws.
Insert and tighten the 2 remaining screws on the
bottom location of the range hood (fig. / ).

• Attach the collar (5) to the range hood (1). Secure

with 2 short screws (8) (fig.

).

0.08”

0.08”

fig.

fig.

fig.

fig.

fig.

NOTE

Sometimes, sponge tape covers the holes. If the
holes are located behind the sponge tape, simply
insert the screw through the sponge tape.

Step 3:
• Mount upper and lower brackets (3, 4) on the

wall. Secure with the remaining 4 sets of long
screws (8). The notches of the lower bracket
should be facing up towards the ceiling (fig. ).

• Attach the exhaust duct. In the example below

a round metal duct furnace pipe has been used.
The airtight connection of the exhaust duct
should then be improved with a duct tape. This
ensures tight fit and that no grease vapors will
escape from the duct (fig. ).

fig.

fig.

Installing the hood

Installing the hood