Wiring the Power Inputs

1. Insert the positive and negative wires into the

V+ and V- contact on the terminal block connector.

2. Tighten the wire-clamp screws to prevent the DC

wires from being loosened. See Figure-2

Notes: The recommended working voltage is DC12V/24V/48V (DC10~60V, 0.8A).

The relay output alarm contacts are in the middle

of the terminal block connector as shown in figure 3.

By inserting the wires and set the DIP switch of the

respective Alarm to “ON”, relay output alarm will

detect any port failures, and form a short circuit.

The alarm relay output is “Normal Open”. See, Figure -3.

Wiring the Earth Ground

In an industrial environment, there might be

a lot of devices that generate electromagnetic

noise, such as AC motors, electric welding

machine, power generator. These devices will

generate electric noise or surges that might

disturb communications. To prevent those noises,

the switch should be well grounded.

Figure 4 shows how proper wiring should be made.

Wiring the Relay Output

Maximum 1A current / DC 24V

Figure-3

Alarm
System

Extra Power
System

Earth Ground
Screw

Earth Ground

Warning: Do not connect to AC line neutral

Figure-4