Led indicators – Westermo DDW-100 User Manual
Page 13

LED Status
Indication
of
PWR
OFF
Unit has no power
ON
Internal power
Slow flash
Initialisation progressing
Fast FLASH
Initialisation error
DSL *
OFF
Unit is unconnected
Flash 1 (200 ms)
Unit is initializing DSL, only CO
Flash 2 (400 ms)
Unit is in activation phase 1of DSL link
establishment
Flash 3 (1 s)
Unit is in activation phase 2 of DSL link
establishment
ON
Unit has established a DSL connection
LINK
OFF
No Ethernet link
ON
Good Ethernet link
Flash
Ethernet data is transmitted or received,
traffic indication
13
6621-2202
LED Indicators
LED Status
Indication
of
SPD OFF
10
Mbit/s
ON
100
Mbit/s
DPX
OFF
HDPX, Half Duplex
ON
FDPX, Full Duplex
* DSL LED indicator
Description
Flash 1 (only in CO)
Both CO and CPE have power and the line is connected
Flash 2 (both in CO and CPE)
Synchronisation phase of DSL link
Flash 3 (both in CO and CPE)
Activation phase of DSL link
ON (both in CO and CPE)
Unit has established a DSL connection