Fibre optic connection – Westermo LD-64F User Manual

Page 10

Advertising
background image

20

6073-2001

Fibre optic connection

1

2

3

4

5

L

N

RS-422/485

POWER

R+

Rx2

Tx1

Tx2

R- T+

T-

1

2

3

4

5

L

N

RS-422/485

POWER

R+

Rx2

Tx1

Tx2

R- T+

T-

R

+

RS-422

equipment

R

T

+

T

RS-485

equipment

T

+

T

*) The designations T+, T–, R+, R– are not standardised and may vary between different

manufactures. The first step in fault finding is to reverse the cables (swap T+ with T–
and/or R+ with R–). Please note that this should be done only at one end!

*

*

LD-64F

RX1

RX2

TX2

TX1

RX1

RX2

TX2

TX1

LD-64F

LD-64F

RX1

RX2

TX2

TX1

RS-422/485

RS-422/485

RS-422/485

Line connection

The alarm connection can for example be used
to control an external relay.

Alarm connections (Opto Link Monitor)

Upon failure the circuit between the contacts C and E is closed.
Please note that the maximum allowed voltage/current is 30 V/80 mA.

In this example only channel 2 is connected. Under normal operation channel 1 and channel 2
should be connected.

LD-64

Rx1

Rx2

TD RD

C

E

PWR

OPTO LINK MONITOR

Ch1

C

E

Ch2

Max 30 V, 80 mA

Relay

+