Specifications, Danger! do not open connected unit switch settings – Westermo MA-42 User Manual

Page 2

Advertising
background image

8

6042-2002

Specifications

Transmission

Asynchronous, full/half duplex or simplex

Interface 1

EIA RS-232-C/RS-423-A
CCITT V.24/V.10
25-position D-sub female, DCE

Interface 2

EIA RS-422/RS-485/CCITT V.11

Data rate

Up to 115,2 kbit/s

Indicators

Power, RD, DCD, CTS, RTS, TD

Insulation

Galvanic insulation with opto-coupler
(data transmission) and transformer (supply)

Insulation voltage

1500V

Overvoltage protection

Mains: Breakdown voltage 440V at
230V AC and 220V at 115V AC
Interface 2: Breakdown voltage transmitter
and receiver 7V
Surge capacity 0.6 kW for 1ms

Power supply

Switchable 115/230V +15/–10% 48-62Hz

Fuse

100 mA fast 5x20mm

Power consumption

Max 25 mA at 230V AC

Temperature range

5–50°C, ambient temperature

Humidity

0–95% RH, non-condensing

Dimensions

161x53x139 mm (WxHxD)

Weight

0.5 kg

Mounting

With rubber pads or screws. Screws:
Remove the two "keyholes" on the bottom of the case.

DANGER! DO NOT OPEN CONNECTED UNIT

Switch settings

The MA-42 can through different switch settings be adapted to a variety of running
conditions. To set the switches, open the plastic case by placing and turning a screw-dri-
ver between top and bottom at the rear of the case.

1 2 3 4 5

V.24/RS-232-C
CONNECTION

LINE

CONNECTION

Advertising