Westermo MCI-211G User Manual

Page 4

Advertising
background image

DIP Switch Settings for Alarm Relay Output and Link
Loss Forwarding

Ȋ

This is a Class 1 Laser/LED product.

Don’t stare into the Laser/LED Beam.

ATTENTION

# 1

Port Event Alarm

#2

Power Event Alarm

#3

LFF

(Link Fault Forwarding)

Pin No. #

Status

ON

ON

ON

Off

Off

Off

Description

To enable port link down alarm at this port.

To enable power failure alarm.

To disable port link down alarm at this port.

To disable power failure alarm.

To disable Link Fault Forwarding function.

To enable Link Fault Forwarding function at both of fiber and copper

port. Once either one of copper or fiber port is disconnected, the

MCI-211G will forced to turn-off the other port to alert the end of

attached device.

Note: Once the LFF is active and the cable event is recovered,

the LFF DIP-switch must be re-triggered to arouse this function.

The SFP Fiber port supports 2 LEDs for link/activity and full duplex/collision; once the gigabit fiber

port is link up, the link LED will be trigger to “ON”.

Advertising