11

6070-2001

Screw

Power

no.

supply

L

115*/230V

N

AC power

PE/Protective Earth

Connections MD-62

Terminal connection (DCE)

(RS-232-C/V.24, 9-position female D-sub connector or 9-position screw-terminal)

Power connection
MD-62 AC
(3-position screw-terminal)

Power connection
MD-62 DC
(2-position screw-terminal)

* MD-62 115V

Connection

Power

no.

Supply

1

– Voltage

2

+ Voltage

Direction

Pin

Screw

CCITT V.24

Description

no.

no.

Circuit no.

I

3

8

103

TD/Transmitted Data

O

2

7

104

RD/Received Data

I

7

6

105

RTS/Request To Send

O

8

5

106

CTS/Clear To Send

5

1 & 9

102

SG/Signal Ground

I = Input O = Output on MD-62

Fibre optic connection

MD-62

TX

RX

TX

RX

MD-62