Interface specifications – Westermo ODW-630-F1 User Manual

Page 11

Advertising
background image

11

6651-22641

Status

Port type

Signal relay, changeover contacts

Rated voltage

Up to 48 VDC

Operating voltage

Up to 60 VDC

Contact rating

500 mA @ 48 VDC

Contact resistance

< 50 mW

Isolation to

Serial port and Power port

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm² (AWG 24 – 12)

Shielded cable

Not required

* External supply current capability for proper startup

RS-422/485

Electrical specification

EIA RS-485, 2-wire or 4-wire twisted pair

Data rate

300 bit/s – 1.5 Mbit/s

Data format

9 – 12 bits

Protocol

Start-bit followed by 8-11 bits

Retiming

Yes

Turning time
(2-wire RS-485)

One t

bit

t

bit

= 1 / Baud rate (Baud rate in bit/s)

Transmission range

< 1200 m, depending on data rate and cable type (EIA RS-485)

Settings

120 W termination and failsafe biasing 680 W

Protection

Installation Fault Tolerant (up to ±60 V)

Isolation to

Status and Power port

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm² (AWG 24 – 12)

Shielded cable

Not required

Interface specifications

Power

Rated voltage

12 to 48 VDC
24 VAC

Operating voltage

10 to 60 VDC
20 to 30 VAC

Rated current

300 mA @ 12 V
150 mA @ 24 V
75 mA @ 48 V

Rated frequency

DC: –
AC: 48 to 62 Hz

Inrush current I²t

0.2 A²s

Startup current*

1.0 Apeak

Polarity

Reverse polarity protected

Redundant power input

Yes

Isolation to

RS-422/485 and Status port

Connection

Detachable screw terminal

Connector size

0.2 – 2.5 mm² (AWG 24 – 12)

Shielded cable

Not required

Advertising