Dip-switch settings, Before setting dip-switches, S2 dip-switch – Westermo ODW-641 User Manual

Page 16

Advertising
background image

16

6650-2291

DIP-switch settings

Before setting DIP-switches:

Prevent damage to internal electronics from electrostatic discharges (ESD)
by discharging your body to a grounding point (e.g. use of wrist strap).

!

S2

S1

S2 DIP-switch

ON

1 2 3 4 5 6 7 8

Multidrop or redundant

ring slave unit.

N/A for ODW-641

ON

1 2 3 4 5 6 7 8

Multidrop end unit. E.g. the first or

last unit in a multidrop network.

Always

"ON" for ODW-641

ON

1 2 3 4 5 6 7 8

Redundant ring master unit.

Only one master unit allowed

in a ring. N/A for ODW-641

ON

1 2 3 4 5 6 7 8

65535 tbit interruption in receiving

frames, until inactive BA

.

ON

1 2 3 4 5 6 7 8

10 seconds interruption in receiving

frames, until inactive BA

*.

ON

1 2 3 4 5 6 7 8

20 seconds interruption in receiving

frames, until inactive BA

*.

ON

1 2 3 4 5 6 7 8

5 seconds interruption in receiving

frames, until inactive BA

*.

* See section “About the automatic data rate detection”

on page 11 for a more detailed description.

Advertising