By-Pass functionality

The by-pass functionality in RFR-212-FB secures connection in case of power failure in
one of the switches. If a switch has power loss an internal relay in RFR-212-FB will by-
pass the switch and bridge two Ethernet ports.

By-pass interfaces
In case of power failure X9 will be by-passed to X11 and X10 will be by-passed to X12.

Internally the switch will bypass

X9.1

Connected to

X11.2

X9.2

X11.1

X9.3

X11.4

X9.4

X11.3

X10.1

X12.2

X10.2

X12.1

X10.3

X12.4

X10.4

X12.3

Note! When by-passing a switch, approximately 5 m (16.4 ft) of the transmission range
(100 m, 328 ft) is consumed. As an example, if a network is intended to cope with a
single car blackout scenario and that two RFR-212-FB in that case will be by-passed, the
total cable distance through the blackout car to adjacent switches on each side of the
blackout car, should not exceed 90 m. (295 ft) Normally, RFR-212-FB can handle longer
distances, up to 150 m (492 ft), but this can not be guaranteed and has to be investigated
case by case. Cable length data is valid for cat5e cable.