Westermo TD-22 User Manual

Page 34

Advertising
background image

35

6177-2203

S10 – Lost Carrier To Hang Up Delay
Sets the length of time, in tenths of a second, that the modem waits before hanging up after a loss of
carrier. When register S10 is set to 255, the modem functions as if a carrier were always present.
The actual interval the modem waits before disconnecting is the value in register S10 minus the value
in register S9. Therefore, the S10 value must be greater than the S9 value or else the modem
disconnects before it recognises the carrier.
Default 14 (1.4 seconds) {1-255} tenths of a second.

S11 – DTMF tone time (Only for USA)
The time a DTMF tone will be activated during dialling.
Default 95 {50..255} thousands of a second.

S12 – Escape Prompt Delay (EPD)
Time before entry/exit of command mode.
Default 50 (1 second) {0-255} fiftieths of a second.

S14 – General Bit Mapped Options Status (Read only register)
Indicates the status of command options.

Bit 0

This bit is ignored.

Bit 1

Command echo (En)
0 =

Disabled (E0)

1 =

Enabled (E1) (Default.)

Bit 2

Quiet mode (Qn)
0 =

Send result codes (Q0) (Default.)

1 =

Do not send result codes (Q1)

Bit 3

Result codes (Vn)
0 =

Numeric (V0)

1 =

Verbose (V1) (Default.)

Bit 4

Reserved

Bit 5

Tone (T)/Pulse (P)
0 =

Tone (T) (Default.)

1 =

Pulse (P)

Bit 6

2/4 wire line interface (AT&H)
0 =

2 wire (&H0) (Default.)

1 =

4 wire (&H1)

Bit 6

Reserved

Bit 7

Originate/Answer
0 =

Answer

1 =

Originate (Default.)