3 quick start guide –xsv venturi loader – AEC Single Conveying Units User Manual
Page 36

XSV-05, XSV-05/R, & XSV-05/2R Single Conveying Units - Venturi Style
35 of 36
6-3
Quick Start Guide –XSV Venturi Loader
Unpack all parts. Check for the following:
• Conveying hopper with level sensor
• Control and maintenance unit
• Venturi
assembly
• Vinyl flexible hose
• Compressed air hose
• Operating
instructions
• Mount the conveying hopper using the flange provided on its base.
• Mount the control module at a location that is readily accessible. Make sure
that the compressed air hose and level sensor cable are long enough to
reach the control module.
• Connect the compressed air supply from the control module to the fitting
located on the material pick up wand.
• Connect shop compressed air to the regulator on the control module.
Compressed air connection must be 70-90 psi (5-6 bar).
• Plus the control module into the main power socket. Make sure that the
correct voltage is being used.
• Adjust the level sensor to sense the material that is being conveyed into the
conveying hopper.
• Maintain the unit as stated in Chapter 5 of this manual.