Troubleshooting

3A1185H

17

Troubleshooting

Problem

Cause

Solution

Unit doesn’t prime

Airleak due to loose suction nut

Tighten suction nut.

Airleak due to worn o-rings

Replace o-ring (108526) on suction seat and
o-ring (867370) below suction seat.

Airleak due to hole in suction
hose

Replace suction hose.

Stuck or fouled balls

Service inlet and outlet valves.

Unit primes but has poor or no
pressure

Pressure set too low

Turn up pressure.

Filter(s) are clogged

Clean or replace gun filter, inlet filter, and/or
manifold filter.

Outlet valve fouled/worn.

Service outlet valve.

Prime/pressure relief valve
bypassing

Clean or replace prime/pressure relief valve
(866428).

Packings and/or piston worn

Tighten packing nut, repack unit.

Unit does not maintain good
spraying pressure

Blown spray tip

Replace spray tip.

Packings and/or pistons worn

Repack unit.

Upper seat worn

Replace upper seat.

Unit does not run

Blown fuse

Replace fuse 20A Slow Blow (331328).

Machine does not start

Control Settings

Make sure machine is plugged into the wall.
Verify the on-off switch is in the ON position
and the pressure control knob is turned all the
way to the right (clockwise for maximum pres-
sure).

Pressure Control Assembly
(Board)

If the power indicating light is still out after
checking the control settings and power
source, replace the pressure control assem-
bly.