Operation

3A1183D

9

Adjusting the Pressure

When adjusting the pressure, turn the Pressure Control
Knob clockwise to increase pressure and counterclock-
wise to decrease pressure. Always use the lowest pres-
sure necessary to completely atomize the material. If
more coverage is needed, use a larger tip rather than
increasing the pressure.

NOTE: Operating the sprayer at higher pressure than
needed wastes material, causes early tip wear, and
shortens sprayer life.

NOTE: Check the spray pattern. The tip size and angle
determines the pattern width and flow rate.

Shutdown

1. Relieve Pressure, page 13.

2. Clean the tip and gun as recommended in the sepa-

rate Gun Manual supplied with the gun.

3. If spraying water-based material or a material that

could harden in the sprayer overnight, flush the
sprayer after use. See Flushing, page 7.

Storage

Short Term

1. Flush sprayer with compatible solvent before stor-

ing, then fill the pump and hoses with an oil based
solvent such as mineral spirits or Graco or Airlessco
Pump Armor.

For oil base paint: flush with mineral spirits

For water-base paint: flush with water, then min-
eral spirits and leave the pump, hose and gun
filled with mineral spirits.

Long Term

For longer storage, use Graco or Airlessco Pump
Armor. Shut off sprayer, Relieve Pressure, page 13,
and make sure prime/pressure relief valve is left open.

Start Up After Storage

Before using water-base paint, flush sprayer with soapy
water and then a clean water flush. When using oil-base
paint, flush out the mineral spirits with the material to be
sprayed.

NOTE: Always store unit indoors.

Optional Air Atomizer

For best performance use at least a minimum of 1
gallon per minute paint sprayer.

For fog finish and fine orange peel use tip #13 or 16
and apply maximum air flow.

For medium orange peel and splatter coat, use tip
#14 or 17 and apply medium air flow.

For heavy splatter coat and knockdown finish use
tip #15 or 17 and apply less air flow.

• To reduce the risk of injection, never hold your

hand, body, fingers or hand in a rag in front of the
spray tip when cleaning or checking for a cleared
tip. Always point the gun toward the ground or into
a waste container when checking to see if the tip is
cleared or when using a self cleaning tip.

• When you spray into the paint bucket, always use

the lowest spray pressure and maintain firm metal
to metal contact between the gun and container.

• To stop the unit in an emergency, turn the engine

off. Then relieve the fluid pressure in the pump and
hose. See Pressure Relief Procedure, page 13

NOTICE

Atomizer must be cleaned after each use, any
debris will cause poor spray performance.

To eliminate the back flow of material into the air
system, always turn the air on first.

Advertising