Technical specifications – Euro-Pro EP621H User Manual

Page 3

Advertising
background image

OPERATING INSTRUCTIONS

GETTING TO KNOW YOUR LIGHTWEIGHT

UPRIGHT VACUUM

Fig. 19

Changing the Belt

• Remove the brush carefully by first

lifting the right side of the brush and

then the left side of the brush. Be

careful not to lose the end caps and

washers (x2). (Fig. 18)

• If the belt has broken, remove any

loose pieces of broken belt before

replacing with new belt.

• To install a new belt, slip one end of

the belt over the gears on the motor

shaft and then slip the other end

over the pulley end of the brush.

• After checking that the end caps

and washers are on correctly,

re-install the brush assembly.

• Turn the brush assembly by hand to

make sure that the belt is not

twisted and all rotating parts turn

freely.

• Replace the brush cover and

screws. (Fig. 21)

IMPORTANT:

This unit is equipped

with a motor protective thermostat. If

for some reason the vacuum cleaner

should overheat, the thermostat will

automatically turn the unit off. Should

this occur:

• Push the On/Off button once.

• Disconnect the plug from the

power source.

• Check the source of overheating

problem. (i.e. clogged hose or

filter)

• If clogged hose or filter is found,

unclog the hose and replace the

filters.

• Wait at least 45 minutes before

attempting to reuse the vacuum.

• After unit has cooled down for

45 minutes, plug in the cleaner

and push the On/Off button. The

vacuum should start again.

• If the vacuum still does not start,

contact customer service at

1 (800) 798-7398.

Motor Thermostat

W

as

he

rs

Fig. 20

E

nd

c

ap

s

9

WARNING:

Always disconnect

from power source when

servicing or cleaning the unit. Failure to

do so could result in electrical shock or

personal injury from cleaner suddenly

starting.
Occasionally the motorized brush drive

belt will require changing, the frequency

will depend upon the amount of use your

vacuum sees.

• Turn unit “Off” and unplug from

wall outlet.

• Remove the motorized floor brush

from the main unit. (see page 4)

• Use a Phillips #1 screwdriver and

remove the two (2) front screws

from the bottom of the motorized

floor brush. (Fig. 18)

Screws

Fig. 18

Fig. 19

• Remove the brush cover. (Fig. 19)

Technical Specifications

Voltage:

120V., 60Hz.

Power:

12 Amps

1.

Hand Grip

2.

Hose/Power Cord Holder

3.

Flexible Hose

4.

Removable Hose Handle

5.

Exhaust Filter Cover

6.

Main Unit

7.

Dust Cup Container

8.

Dust Cup Release Lever

9.

Extension Tube

10. On/Off Switch
11. Lifting Handle
12. Crevice Tool
13. Dusting Brush
14. Motorized Floor Brush
15. Quick Release Cord Holder
16. Lower Cord Holder
17. Lower Hose Holder
18. Inlet Hose
19. Power Cord
20. Brush Roll Warning Light
21. Manual Variable Suction

Control

22. Trap Door Release Button
23. Intelli-Sense

TM

Filter Monitor

24. Hose Clip

2

Advertising
This manual is related to the following products: