Troubleshooting guide – Atlantic Water Gardens FP100 User Manual

Page 6

Advertising
background image

1-877-80-PONDS

www.atlanticwatergardens.com

Problem

Possible Cause

Possible Solution

Pump does
not run

Power is off

Turn power on

Power failure

Check power supply or
contact local power company

Power cord is not
connected

Connect power cord

Impeller is stuck

Remove debris/clean impeller

Pump stops after
starting

Pump is
overheating

Submerge pump/Raise water level/
Allow pump to cool/Clean impeller

Power/Current
overload

Check length/size of power cable.
Check or replace GFI

Intake is blocked/
Impeller needs cleaned

Remove debris from the pump
intake. Refer to page 5 for
cleaning instructions.

Diminished
flow rate or
no water flow

Impeller needs cleaned

Refer to page 5 for cleaning instructions

Obstruction in pump
or piping

Clear obstruction

Low water level

Stop operation/Raise water level

Air-lock in the
impeller chamber

Place pump in water. Turn the pump
ON/OFF intermittently 2 or 3 times.

Troubleshooting Guide

Always turn off power before inspecting the pump. Failure to observe this precaution can
result in a serious accident.

Before ordering repairs, carefully read through this instruction booklet. If the problem
persists, contact your dealer.