Prior to operation and installation, Caution, Introduction – Atlantic Water Gardens MD250 User Manual

Page 2: Flow chart: (gph)

Advertising
background image

Prior to Operation and Installation

• When the pump is delivered, first perform the following checks:

• Check for any damage to pump and power cable that may have occurred during

the shipment.

• Check the model number to make sure it is the product that was ordered and verify

the voltage and frequency are correct.

Caution

• DO NOT operate this product under any condition other than those for which it is

specified. Failure to observe this precaution can lead to electrical shock, electrical

leakage, fire, water leakage or other problems.

• The pump is a 110/120 volt 60 Hz pump, please only use with a power supply voltage

within 110-120 volt 60 Hz.

• Never place your hand or any object in or near the inlet opening while this equipment is

operating. If pump inlet is clogged, always turn off the power supply and wait until the

motor is completely stopped before attempting to remove any clogged material.

• Please make sure that the power plug and the AC outlet receptacle are protected and away

from water or pump discharge hose to prevent accidental electric shock or short circuit.

• Always operate the pump completely submerged in water.

• Avoid dry operation, which will not only lower performance but can cause the pump to

overheat/malfunction, leading to electrical leakage, shock or premature failure.

• Always turn off power or unplug the pump prior to performing any maintenance or

placing your hands into the water.

Introduction

Thank you for selecting the TidalWave MD250, MD350, MD550, MD750, MD1000,
MD1250, MD1500 or MD2000 series pump. Before using this pump please take a
moment to review this manual.

To avoid an accident do not use the pump in any way other than as described in this
manual. Please note the manufacturer cannot be responsible for accidents arising because
the product was not used as prescribed. After reading this manual keep it as a reference
in case questions arise during use.

2

Flow
Chart:
(GPH)

MD1000, MD1250, MD1500 and MD2000 pumps include an 1½” adaptor for use with the Triton Check
Valve and Atlantic Plumbing Kits. This adaptor makes the discharge height of the Mag Drive Series
pumps equal to the TW2400 pump. If using a Mag Drive Series pump with the Triton Check Valve,
Colorfalls Kit or Fountain Basin Plumbing kits, please reference the plumbing instructions for a TW2400
as outlined in the installation manuals for these items.

Max 5’ 10’ 15’ 20’

Model #

Watts

15
25
40
50
90

120
165
250

MD250
MD350
MD550
MD750

MD1000
MD1250
MD1500
MD2000

300
370 145
650 385
790 465
1080 785 275
1330 1040 580
1560 1255 780
2010 1695 1320 695

Advertising