Problem

Possible Cause

Possible Solution

Air pump does

not start

Power is off

Turn power on

Power failure

Check power supply or

contact local power company

Voltage drop/

Overload

Check/Replace the GFI (Ground

Fault Interrupter)

Power cord is not

connected

Connect power cord

Air pump stops

after starting

Air pump is

overheating

Allow pump to cool

Power/Current

overload

Check length/size of power cable.

Check or replace GFI

Diminished

air flow rate or

no air flow

Kink/damaged tubing

Repair/replace tubing

Dirty filter media

Clean filter media

Worn/damaged

diaphragm

Consult your dealer. Replace

diaphragm and flappers

Air line is submerged

below operating depth

Raise air line to desired depth

7

Troubleshooting Guide

Always turn off power before inspecting the pump. Failure to observe this precaution can
result in a serious accident.

Before ordering repairs, carefully read through this instruction booklet. If the problem per-
sists, contact your dealer.