Step Command

Remarks

3.

Bind a physical

interface to the IRF
port.

port group interface
interface-type
interface-number
[ mode

{ enhanced | normal } ]

By default, no physical interfaces are bound to
any IRF port.
Repeat this step to assign multiple physical
interfaces to the IRF port.
Each IRF port can have a maximum of eight
physical interfaces.
When you bind physical interfaces to an IRF

port, set all the physical interfaces to the same
mode: enhanced or normal.
If you do not specify a mode, the enhanced
mode applies.

Saving configuration to the next-startup

configuration file

Save the running configuration before converting to the IRF mode. The mode change requires a reboot,

which causes all unsaved settings to be lost.
Perform the following task in any view:

Task Command

Save the running configuration to
the next-startup configuration file. save [ safely ] [ backup | main ] [ force ]

Connecting IRF physical interfaces

Connect the devices into a daisy chain.
When you connect two neighboring IRF members, connect the physical interfaces of IRF-port 1 on one

member to the physical interfaces of IRF-port 2 on the other (see

Figure 15

).

IMPORTANT:
•

Do not connect physical interfaces of both IRF ports on one member device to the physical interfaces of
both IRF ports on the other.

•

No intermediate devices are allowed between neighboring members.

Figure 15 Connecting IRF physical interfaces