Configuration
Standard Selection
The Standard Selection display is shown in Auto mode in
. In this
mode, if the module does not detect a valid data rate, the
Current Bit Rate
will
display
Bypass.
Figure 9. Standard Selection Display in Auto Mode
To select one input signal standard, pull down the
Selection
window and
choose
Manual
. After selecting manual mode, click the
Apply
button to acti-
vate it. In manual mode (see
), a pull-down window is available
to choose one of the various input standard data rates.
Figure 10. Manual Standard Selection Display
Use
This
Link
A valid input data rate
has not been detected
Manual allows
selection of a specific
Input signal data rate
These selections appear
in manual mode only