Specifications, Specifications on – Grass Valley 7600REF Installation User Manual

Page 15

Advertising
background image

7600REF — Installation and Safety Manual

15

Specifications

Specifications

The specifications for the 7600REF Reference Generator frame are given in

Table 1

.

Table 1. 7600REF Frame Specifications

Parameter

Value

Frame Dimensions

Width

19 in. rack mounting

Height

44 mm (1.73 in.) 1 Rack Unit

Depth

433 mm (17.0 in.) excluding connectors

Weight

4 kg (8.82 lbs) no option modules
5 kg (11 lbs) maximum with option modules

Operating temperature range

0 to 45 degrees C

Storage temperature range

-25 to 70 degrees C

Operating humidity

95% RH non-condensing

Power

Input voltage range

100-240 VAC, 50-60 Hz

Maximum input current

1.4 Amps

Internal fuse

3.15 Amps

Miscellaneous

Setup data retention when unit not
powered

> 1000 hours. Unit must have been powered for > 24 hours prior to this.

Serial communication type

RS422/232 (software configured)

Power fail indication

Relay contact, closed under normal operation, open for any failure state.

Fan fail indication

Relay contact, closed under normal operation, open for any failure state.

Remote inputs

Two grounding inputs provided on Sub-D connector.

Remote outputs

Two outputs provided on Sub-D connector. Open collector outputs rated at
45V/500mA maximum.

Option interfaces

Up to three single width option modules may be installed in the unit.

Ethernet

RJ-45 interface. Software configured for DHCP or static IP address.

Advertising