Remote configuration and monitoring, 8900net module information, Newton control panel configuration – Grass Valley 8920ADC v.2.0.1A User Manual
Page 19: Ol and monitoring
 
8920ADC Instruction Manual
19
Configuration
Remote Configuration and Monitoring
8920ADC configuration and monitoring can be performed using a web 
browser GUI interface or a networked Newton Control Panel when the 
8900NET Network Interface module is present in the video frame (Gecko 
8900TFN-V frame). Each of these interfaces is described below.
Note
For remote access, make sure the jumper block on the module is set for both 
Local and Remote access (
8900NET Module Information
Refer to the 8900NET Network Interface Module Instruction Manual for 
information on the 8900NET Network Interface module and setting up and 
operating the Gecko 8900 frame network.
Note
The 8900NET module in the frame must be running software version 3.2.0 or 
higher for proper remote and control panel operation. Upgrade software and 
instructions for the 8900NET can be downloaded from the Grass Valley web 
site.
Newton Control Panel Configuration
A Newton Control Panel (hard or soft version) can be interfaced to the 
Gecko 8900 Series frame over the local network. Refer to the documenta-
tion that accompanies the Newton Modular Control System for installa-
tion, configuration, and operation information.
Control panel access offers the following considerations for module config-
uration and monitoring:
•
Ability to separate system level tasks from operation ones, minimizing 
the potential for on-air mistakes.
•
Ability to group modular products—regardless of their physical loca-
tions—into logical groups (channels) that you can easily manipulate 
with user-configured knobs.
•
Update software for applicable modules and assign frame and panel IP 
addresses with the NetConfig Networking application.
•
Recommended for real-time control of module configuration parame-
ters, providing the fastest response time.
Note
Not all module functions are available with the control panel, such as E-MEM 
and factory default recalls. The available control panel controls for the 
8920ADC module are listed in 
.
An example of the Newton Configurator is shown in
.