8972PX — Instruction Manual
39
Installation
GPI Relay Status Monitoring
The rear module GPI I/O connector also provides tally connections to 
report to the external GPI device the input signal status of what input signal 
is currently on the Program output and if any of the input signals have 
failed. The Program output active and failure reporting status of the Pri-
mary, Secondary, and Alternate inputs can be monitored by the GPI device.
The solid state relays are bi-directional; either polarity voltage can be 
applied. It can be used to drive downstream DC relays. Each tally output is 
active on a steady closure state.
Examples are given in
for both logic connections and
12V lamps to an external system. Refer to
for a complete
list of GPI function pin numbers.
Relay outputs specifications are maximum current of 0.5A (continuous) or 
1.5A peak (100 ms), 60V peak load voltage.