GUIDE TO INSTALLATION AND OPERATION

6 | FLO-1601

• Use the keys on the local control panel to step through the displayed menu to configure and adjust

the FLO-1601.

FLO-1601 MENU

STATUS

STATUS

OK

NO RF INPUT

(< -60 dBm)

WEAK RF INPUT

(< -55 dBm)

OPTICAL OUT FAIL


RF SIG STRENGTH

[-60 dBm, -59 dBm, -58 dBm,….., -1 dBm, 0 dBm] (read-only)



OPTICAL

OUT

[ON, OFF]



LNB

POWER

[OFF, +13V, +18V]



USER PRESET

LOAD

[USER 1, USER 2, USER 3, USER 4, USER 5]


SAVE

[USER 1, USER 2, USER 3, USER 4, USER 5]



CONFIG ALARMS

NO RF INPUT

ALARM LEVEL

[GREEN, YELLOW, RED, FLASH RED]


ALARM

REPORT [NONE, GPI]


WEAK RF INPUT

ALARM LEVEL

[GREEN, YELLOW, RED, FLASH RED]


ALARM

REPORT [NONE, GPI]


OPTICAL OUT FAIL

ALARM LEVEL

[GREEN, YELLOW, RED, FLASH RED]


ALARM

REPORT [NONE, GPI]

VERSION

FLO-1601:xxx


FACTORY

DEFAULT

[RESTORE]


Notes on the menu items:

OPTICAL OUT – turn the laser ON or OFF

LNB POWER – Turn the power sent to the LNB (Low Noise Block Converter) via the RF input connector
OFF, or select the LNB voltage as +13V or +18V.

USER PRESET – the FLO-1601 has 5 registers that can store full configuration data. Use the LOAD and
SAVE menu items to select a register (USER 1 to USER 5) and either save the current configuration into that
register (SAVE) or reconfigure the FLO-1601 according to the contents of the register (LOAD).

CONFIG ALARMS / ALARM LEVEL – for each alarm, set the color that will be displayed on the FLO-1601’s
status LED.

CONFIG ALARMS/ ALARM REPORT – for each alarm, select whether that alarm will be reported on the
Densité frame’s GPI output. See the manual for the frame’s controller card for more information about this
feature.