Icontrol – Grass Valley iControl Supported Devices V.2 User Manual

Page 17

Advertising
background image

iControl

Supported Device Reference Guide

9

Alarm name

Further details

numberOfSignals

 

The number of signals configured in the PNC. The current PNC supports up to
4 signals. The maximum number of signals may change in future versions of
the PNC.

pncAppStartTime

 

PNC application start time:

<year>-<month>-<day>@<hour>:<minute>:<second>

where

<year>

:= 4 decimal digit year

<month>

:= 2 decimal digit month 1..12

<day>

:= 2 decmial digit day of month 1..31

<hour>

:= 2 decimal digit hour 0..23

<minute>

:= 2 decimal digit minute 0..59

<second>

:= 2 decimal digit second 0..59

pncAppStatus

 

PNC application status:

0

: Running OK

1

: Not running

2

: Starting up

3

: Shutting down

4

: Not installed

pncAppVers

 

PNC application version:

<major version>.<minor version><patch level>{-<option list>}

where

<major version>

:= decimal major version number

<minor version>

:= 2 digit decimal minor version number

<patch level>

:= [a..z]

<option list>

:= <option name>...

<option name>

:= text string name of the option

(e.g.

4.00g-

Bitmizer,Conditional_Access,Cue_Trigger,Disaster_Recovery,Dpi,MetroMu

x

)

pncPlatformStatus

 

Result of command:

prtdiag

found in

/usr/platform/sun4u/sbin

0

: no failures detected

1

: failures detected

pncPlatformSystemDate

Result of command:

/usr/bin/date

pncPlatformVers

 

Result of command:

/usr/bin/uname -a

Advertising