13

Fixed in Version 3.60

[Ref. #15314]

When Densité services are often stopped and restarted by Standby/Online

actions made with a Densité Manager, an OutOfMemory error may eventually result.

[Ref. #25942]

On the IRD-3802 and IRD-3811 Densité cards, the service panel may become

unresponsive and may close when TR 101 290 probing is enabled.

[Ref. #23288]

On the HMP-1801 Densité card, the control panel may not reflect the correct

card mode when toggling between RECORD and PLAYBACK modes.

[Ref. #25525/25578]

On the HMP-1801 Densité card, the GPI configuration of both RECORD

and PLAYBACK modes may not work properly.

[Ref. #25554]

On the HMP-1801 Densité card, the Thumbnail and ALM panels may have

unexpected behaviors including:

The aspect ratio of the thumbnail may be incorrect.

The ALM speed may be incorrect.

The Thumbnail and ALM are disabled when switching from PLAYBACK to RECORD
modes, and vice versa.

[Ref. #25428]

On the HMP-1801 card, alarms may not be saved correctly at all times.

Known Issues and Limitations

The following is a list of known issues and limitations associated with iControl Solo. The star
(

) symbol indicates a new issue in iControl Solo version 4.13.

[Ref. #29836]

IRD-3811: If your video output is SD and your reference is HD, the audio may

not process correctly when either of the following conditions are true:

You have analog audio synchronized on an SDI output.

Your audio is de-embedded by a de-embedder with the same reference as the IRD card

[Ref. #29503]

If your Densité cards have firmware enabling support for fingerprint

configuration, the control panels for these cards within iControl Solo will show fingerprint
controls, even if the version of iControl Solo you are using does not support it. In this case,
even if there are incoming lipsync and reference signals, iControl Solo is unable to detect,
compare, nor analyze them.

[Ref. #25584]

On the HMP-1801 Densité card, profiles are not yet implemented on the

control panel.

[Ref. #24876]

In the case of certain Densité cards, although their control panels are visible in

the iControl Solo context, features related to User Defaults are not supported.

[Ref. # 23578]

In iControl Solo Navigator, after you disable audio in the player and then re-

enable it, or when you change the size parameter, the card no longer produces sound.

Workaround:

Close then reopen the card’s control panel.

[Ref. #21532]

In the Densité Manager’s Target Information window (on the DensiteManager

control panel’s Configuration tab, click Add), the Redundancy Configuration and Mode
sections are not relevant in the context of iControl Solo.