MAESTRO — Automation Interface Protocol Technical Reference Manual
129
MAESTRO_KEYER_SELECT
MAESTRO_KEYER_SELECT
Hex definition
Mnemonic
0x30
MAESTRO_ KEYER_SELECT
Command format:
<PREAMBLE>
MAESTRO_KEYER
_SELECT
<keyer> <select> <destInputBus>
Query format:
READ
<PREAMBLE>
MAESTRO_KEYER
_SELECT
<keyer> <destInputBus>
Reply format:
IFRE
<PREAMBLE>
MAESTRO_KEYER
_SELECT
<keyer> <select> <destInputBus>
Use applicable with UPDATE:
Yes
Argument definitions:
<keyer> = 1-8
1= Keyer 1
MAESTRO_KEY_01
2= Keyer 2
MAESTRO_KEY_02
3= Keyer 3
MAESTRO_KEY_03
4= Keyer 4
MAESTRO_KEY_04
5= Keyer 5
MAESTRO_KEY_05
6= Keyer 6
MAESTRO_KEY_06
7= Keyer 7
MAESTRO_KEY_07
8= Keyer 8
MAESTRO_KEY_08
<select> = 0-1
0 = Unselect
MAESTRO_UNSELECT
1 = Select
MAESTRO_SELECT
<destInputBus > = 0-2
0 = Preset
IB_PRESET
1 = Program
IB_PROGRAM
2 = Auxiliary
IB_AUXILIARY