Configuration, Quick look – Grass Valley Trinix v.2.4.1 User Manual
Page 81

Configuration
Planning and Installation Manual
81
Configuration
Quick Look
Building block size: 32 Inputs or 32 Outputs
Options:
SD or HD rate I/O modules
Dual outputs, quad outputs
Additional monitor outputs (2)
Redundant sync inputs (2)
Redundant monitor/status/control
Redundant power supplies
Standards supported: SMPTE 259M-1997, SMPTE 292M-1998
Standard connectors: 75-Ohm BNC
Output monitor:
Yes, 2 standard
Sync reference input: Yes, 2. Granularity: per 32 outputs
Control options:
Jupiter, SMS 7000, Encore
Chassis, Board, Weight and Power Summary for Select Matrix Sizes
Table 13.
*Approximate
Matrix Size
32
x
32
64
x
64
96
x
96
128
x
128
160
x
160
192
x
192
224
x
224
256
x
256
128 Chassis
256 Chassis
# of Chassis
1
1
1
1
1
1
1
1
# Input Boards
1
2
3
4
5
6
7
8
# Output Boards
1
2
3
4
5
6
7
8
# of Matrix Boards
1
1
1
1
4
4
4
4
Weight in pounds
(kilograms)
75
(34)
81
(37)
88
(40)
94
(43)
163
(74)
169
(77)
176
(80)
182
(83)
Power Consumption* (W)
~350
~400 ~440 ~480
~850 ~900
~950 ~1000