Vertical interval trigger – Grass Valley TTN-BVS-0808 User Manual
Page 17

BVS-0808
Rev. 2
9
C4
8 C4
8
RGBS
RGBS Signal Input
RGBS Signal Output
S1
1 S1
1
S2
2 S2
2
G1
3 G1
3
G2
4 G2
4
B1
5 B1
5
B2
6 B2
6
R1
7 R1
7
R2
8 R2
8
5.3 Vertical interval trigger
The BVS-0808 router provides vertical interval switching. Video input 1 is used as VIT reference. For all
possible video formats the sync carrier has to be connected to video input 1.
Switch 7 on the configuration switch enables or disables the VIT sensing on video input 1. If VIT
switching is enabled but a proper signal is missing, the router will automatically switch without VIT.
The VIT can be switched according to the following pattern:
-
means switch down
*
means switch up
Switch
7
VIT
-
disabled
*
enabled
Default is VIT enabled.