Epson S050192 User Manual

Page 3

Advertising
background image

______________________________________________________________________________________________________
PIS # S050192 Version 3.8 (USA)
Page 3 of 4 Release Date 09/01/12

Softening point:

120

– 130 deg. C

Flash point: >230 deg. F / 110 deg. C (CC)

Auto flammability: Over 300 deg. C

Explosive properties:

None

Oxidizing properties:

None

Vapor density:

Not applicable

Relative density:

1.12 at 68 deg. F / 20 deg. C

Solubility in water: Negligible

Solubility in fat:

No data available

Partition coefficient:

No data available

Viscosity:

Less than 5mPa-s


10. Stability and Reactivity


Stability:

Stable

Hazardous polymerization: Will not occur

Hazard decomposition products: None

Incompatible materials:

Oxidizers and explosives


11. Toxicology and Health Hazards


Routes Of Overexposure: Eye, skin, inhalation, and oral


Acute Health Hazards:

Overexposure of eye surface to toner may be mildly irritating

Overexposure of skin to toner contact may cause irritation and in some people swelling and redness

Intentional inhalation overexposure to toner may result in respiratory tract irritation

Intentional or accidental oral ingestion may cause an upset stomach


Chronic Health Hazards:

Use of this product, as intended, does not result in inhalation of fugitive excessive

dust. In an inhalation study with rats chronically exposed to a typical developer, a
mild to moderate degree of lung fibrosis was observed in approximately 90% of rats
in the high concentration exposure group (16mg/cubic meter), and a minimal to mid
degree of fibrosis was noted in approximately 20% of the animal in the middle
exposure group (4mg/cubic meter). But no pulmonary change was reported in the
lowest exposure group (1mg/cubic meter), the most relevant level to potential
human exposure.



Carcinogenicity:

With excessive exposure, carbon black has been listed as a possible human

carcinogen. However, as engineered within this toner cartridge, emissions to air of
carbon black during normal printing use has not been found. IARC, the
International Agency for Research on Cancer, has found printing toners to be not
classifiable as human carcinogens.

Titanium dioxide is classified as “possibly carcinogenic to humans” (Group 2B). In

animal chronic inhalation studies, the tumor formulation observed in only rats with
animal chronic inhalation is

attributed to “lung overloading”, a generic response to

excessive amounts of any dust retained in the lungs for a prolonged interval. Use
of this product, as intended, does not result in inhalation of excessive dust.
Epidemiological studies to date have not revealed any evidence of the relation
between exposure to titanium dioxide and diseases of the respiratory tract beyond
the general effects of dust.


Toxicity Data:

Oral LD50 Dermal LD50 Inhalant LC50

OSHA Regulated?

>5000mg/kg(Rats) >5000mg/kg(Rats) 4.1mg/L/4hr(Rat)

Not Established

Advertising