Blast Chiller/ Freezer - 56 kg 10 GN2/1

Chilling means bringing the temperature of cooked food from +90ºC to +3°C in a short time lap which does not allow
bacterial growth .Electrolux Blast Chillers/Freezers reduce temperature from +90ºC to +3°C at food core in less than 90
minutes and down to -18ºC in less than four hours: the model detailed on this sheet performs this cycle up to a 56 kg full
load. After the Blast Chilling/freezing process a holding cycle starts automatically to maintain food at -18 °C. Blast chilled
food has a solid 5 days shelf life without loss of flavour, nutritional values and weight. The opportunity to prepare in a
single shot the food to be used in different times during the week enables a better work scheduling and therefore a
sensible reduction in labour costs. The range of Electrolux Blast Chillers/freezers consists of models with built in
refrigerating unit that offer an excellent all-round performance.

726046

OPERATING MODES

•

Soft Chilling (Air temperature –2°C).

•

Hard Chilling (Air temperature

–20°C).

•

All the probe-driven cycles feature

ARTE (Algorithm for Remaining Time
Estimation) to make planning the
activities easier.

•

Holding at +3°C (automatically

activated at the end of each cycle).

•

Turbo cooling: the chiller works

continuously at the desired
temperature. Ideal for continuous
production.

•

Automatic recognition of the

insertion of the food probe (cycles
piloted either by food probe
temperature or by time).

•

The control unit provides several

operating settings: time/core
temperature according to NF and UK
regulations, time/air
temperature/probe personalised
according to national regulations,
sterilizing cycle: UV lamps built-in (on
request), 3 single sensor or 3-sensor
temperature probes (as accessory),
ideal for meats, automatic defrosting
and manual defrosting. All parameters
are programmable.

•

Single sensor core probe as

standard.

•

The control unit provides two large

displays to read out: time, core
temperature, cycle countdown,
alarms, service information.

•

Two customizable cycles (P1 & P2)

for each operating mode, allowing to
set the time and air temperature.
These programs can be converted
into ice-cream specialized cycles
(shape maintainance and holding).

•

All information related to the

different operating models are
recorded: date, time, cycle, core
temperature, holding temperature,
HACCP accordance.

•

An audible alarm starts when the

cycle ends or terminates abnormally.

PERFORMANCE

•

Chilling times can vary according to

food quantity, density, moisture
contents and type of containers.

Advertising