16

Audio recording is activated / deactivated in the Camera Menu for Camera #1~16 respectively. Please

check and always comply with local laws and regulations when using audio recording.
The audio channel is always recorded together with video and is independent of the image recording rate.

Though the audio record control is done in the Camera #1~16 screen, there is no specific camera
allocation.

2.3 ALARM CONTACTS INSTALLATION

The alarm inputs can be used to start recording or for recording rate adjustment. In addition, alarm

reactions such as camera display on the monitor, buzzer, e-mail and network alarm are available. The
alarm output relay can be switched if required. Alarm input response actions can be controlled according to

a flexible schedule.

2.3.1 Alarm Input Contacts

This DVR provides one alarm input per camera. All inputs are programmable N.O. (Normal Open) or N.C.

(Normal Closed) Inputs have to be switched by dry contacts.

Alarm input with N.O. (Normal Open) contact

Alarm input with N.C. (Normal Closed) contact

in

idle

state

in

idle

state

All settings are programmed in the ALARM menu (Section 0).

2.3.2 Alarm Output Relay

The relay output provides either Normally Open or Normally Closed dry contacts.

Output relay in idle state

2.4 RS-485 keyboard / PTZ Installation

All functions can be remote-controlled by the EKB-500 universal keyboard. Using the EEPbus protocol,

digital video recorders, keyboards and speed domes can be installed on one single RS-485 bus. One
system can comprise up to 8 keyboards.