Electrical, Mechanical, Paper – Epson Sylus Pro 10600 User Manual

Page 2: Environmental, Safety approvals, Ink cartridges, Electrical mechanical paper, Environmental safety approvals ink cartridges

Advertising
background image

EPSON Stylus Pro 10600

2 - EPSON Stylus Pro 10600

9/02

Electrical

Mechanical

Paper

The allowable paper dimensions are shown below:

Notes:

❏ Poor quality paper may reduce print quality and cause paper jams

and other problems. If you encounter problems, switch to a
higher grade of paper.

❏ Do not use curled, folded, or deckle-edge paper.
❏ Depending on the media, best feed and print quality are

guaranteed on EPSON paper with thicknesses of 3.15 to 4.33 mil
(0.08 to 0.11 mm), 64 to 90 gsm.

❏ For best results, use paper under the following conditions:

Temperature:

59 to 77 °F (15 to 25 °C)

Humidity:

40 to 60% RH

Environmental

Safety Approvals

Ink Cartridges

Specification

120V Model

220

−240V Model

Input voltage range

90 to 132V

198 to 264V

Rated frequency range

50 to 60 Hz

Input frequency range

49 to 61 Hz

Rated current

1.4 A

0.7 A

Power consumption

Approx. 131 W (ISO 10561 Letter Pattern)
30 W or less in sleep mode

Dimensions

Width: 73.4 inches (1865 mm)
Depth: 28.0 inches (710 mm)
Height: 48.2 inches (1225 mm)

Weight

284 lb (129 kg) with stand

Roll paper

Cut sheets

Size

8.3 to 44 in. wide
(210 to 1118 mm)

8.5 × 11 in. up to 44 in.
wide

Maximum
external roll
diameter

2 in. core: 4 in. (103 mm)
3 in. core: 6 in. (150 mm)

—

Thickness

3.15 to 19.7 mil (0.8 to
0.5 mm)

3.15 to 59 mil (0.8 to
1.5 mm)

Temperature

Operation: 50 to 95 °F (10 to 35 °C)
Storage:

–

4 to 104 °F (

–

20 to 40 °C)

1 month at 104 °F (40 °C)

Transit

–

4 to 140 °F (

–

20 to 60 °C),

stored in shipping container
120 hours at 140 °F (60 °C)

Humidity
(without
condensation)

Operation: 20 to 80% RH
Storage:

20 to 85% RH

Transit

5 to 85% RH (stored in
shipping container)

Safety standards UL 1950, CSA C22.2 No. 950 FDA

EMC

FCC part 15 subpart B, class A,
CSA C108.8 class A

Cartridge life:

Photographic Dye ink
2 years from production date

UltraChrome and Archival ink
2 years from production date if unopened;
within 6 months after opening package, at
77 °F (25 °C)

Temperature:

Storage (uninstalled):

–

22 to 104 °F (

–

30 to 40 °C); 1 month at 104

°F (40 °C)

Storage (installed):

–

4 to 104 °F (

–

20 to 40 °C); 1 month at 104

°F (40 °C)

Transit

:

–

22 to 140 °F (

–

30 to 60 °C); 1 month at 104

°F (40 °C), 120 hours at 140 °F (60 °C)

Freezing:
14 °F (

–

10 °C); ink thaws and is usable after

at least 3 hours at 77 °F (25 °C)

Capacity

500 ml

Advertising