Event number

Message, cause and corrective measures

7326

Webconnect update failed
Update of Webconnect module failed.
Corrective measures:

• Retry update.
• If the error recurs, contact the SMA Service Line.

7508

External fan fault > Replace fan
One of the fans is blocked.
Corrective measures:

• Clean the fans (see Section 10.3, page 54).
• If the message continues to be displayed, replace the fan (see Section 15

"Spare Parts and Accessories", page 75).

7701 to 7703

Self diagnosis > Interference device
The cause must be determined by the SMA Service Line.
Corrective measures:

• Contact the SMA Service Line.

8001

Derating occurred
The inverter has reduced its power output for more than ten minutes due to ex-
cessive temperature.
Corrective measures:

• Clean the cooling fins on the rear of the enclosure and the air ducts on

the top using a soft brush.

• Clean the fans (see Section 10.3, page 54).
• Ensure that the inverter has sufficient ventilation.

8101 to 8104

Communication disturbed
The cause must be determined by the SMA Service Line.
Corrective measures:

• Contact the SMA Service Line.

8204

AFCI self-test failed
The cause must be determined by the SMA Service Line.
Corrective measures:

• Contact the SMA Service Line.