1. To wire Junction Box Receptacle, remove the tab on the side of the

receptacle (hot side) to split receptacle. This will be required to

separate blower and valve circuits.

2. Power for switched and live sides of Duplex Receptacle must come

from the same power source. (One circuit breaker on main panel must

switch all power off.)

3. From the wall box to the fireplace a 3-wire conductor with ground is

recommended, however (2) two-wire conductors with grounds may be

used in place of a 3-wire conductor with a ground if the black wires

from the thermostat and blower switch are identified.

4. Two wall switches, or a wall switch and thermostat may be used to

activate the two receptacle plugs independently.

The intermittent pilot (120/24 volt system) is ON when the main

burner is ON. When the main burner is OFF the intermittent pilot

is OFF.
The pilot flame should envelop 3/8 to 1/2 inch (10 to 13 mm) of

the tip of the flame rod.
To adjust:

1. Remove the pilot adjustment cover screw.

2. Turn the inner adjustment screw clockwise

to de-

crease or counterclockwise

to increase pilot flame.

Pilot adjustment is shipped at full flow rate. Turn the inner

adjustment screw clockwise

if the inlet pressure is

too high.

3. Replace the cover screw after the adjustment to prevent gas

leakage.

Label all wires prior to disconnection when servicing controls.

Wiring errors can cause improper and dangerous operation.

Verify proper operation after servicing.

Figure 70

Provided on the intermittent pilot wiring harness are two (2) stripped

and bare wires that are labeled THERMOSTAT. The wires will be

used for attachment of 24 volt thermostat, optional FWS-1 wall

switch or will attach into the receiver on an optional FRBC, FRBTC

or FREC remote control.
Installation of Remote Receiver

Place remote receiver on the floor of fireplace behind the louver as

far forward as possible.
Attention: The Velcro loop and hook are not necessary in this

installation but can be used to secure remote receiver.

ELECTRICAL CONNECTION (Figure 70)

The DVX Intermittent Pilot Models with optional fan requires 120

VAC electrical hookup to the electrical box (installed).
The appliance, when installed, must be electrically grounded in

accordance with local codes or, in the absence of local codes,

with the National Electrical Code, ANSI/NFPA 70, if an external

electrical source is utilized.

CAUTION: ALL WIRING SHOULD BE DONE BY A QUALI-

FIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH

ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE

MAKING THE ELECTRICAL CONNECTION, MAKE SURE

THAT MAIN POWER SUPPLY IS DISCONNECTED. THE AP-

PLIANCE, WHEN INSTALLED, MUST BE ELECTRICALLY

GROUNDED IN ACCORDANCE WITH LOCAL CODES OR,

IN THE ABSENCE OF LOCAL CODES, WITH THE NATIONAL

ELECTRICAL CODE ANSI/NFPA 70 (LATEST EDITION).

Figure 71

INTERMITTENT PILOT OPERATING INSTRUCTIONS

INTERMITTENT PILOT WIRING DIAGRAM