ROM Fatal Systems Errors
ROM fatal errors may be corrected by cycling the radio power (turn it off then on). When the power cycle does not
correct the problem the radio must be serviced.
ERROR NAME
MESSAGE
CODE
DESCRIPTION
FATAL_SYS_TRAP
HARDWARE
0
Fatal system error trap number.
FATAL_NMI_ERROR
HARDWARE
1
NMI occurred outside of sleep.
FATAL_RAM_ERROR
HARDWARE
2
8K RAM test error.
FATAL_ROM_CHKSUM
HARDWARE
3
32K ROM checksum test error.
FATAL_FLSH_CHKSUM
HARDWARE
4
Flash checksum test error.
FATAL_ASIC_LOAD
HARDWARE
10
ASIC driver failed initialization.
FATAL_ICP_LOAD
HARDWARE
11
ICP driver failed initialization.
FATAL_ASP_LOAD
HARDWARE
12
ASP driver failed initialization.
FATAL_EE_LOAD
HARDWARE
13
EEPROM driver failed initialization.
FATAL_ICP_PORTNIT
HARDWARE
14
ICP digital I/O initialization failed.
FATAL_INTOUT_LOAD
HARDWARE
15
Standard input/output driver failed initialization.
FATAL_INTIN_LOAD
HARDWARE
16
Standard input driver failed initialization.
FATAL_RADIO_LOAD
HARDWARE
17
RADIO driver failed initialization.
FATAL_MODEM_LOAD
HARDWARE
18
MODEM driver failed initialization.
FATAL_EXTIO_LOAD
HARDWARE
19
External I/O driver failed initialization.
FATAL_SCI_LOAD
HARDWARE
20
Serial communication interface driver failed initialization.
FATAL _ICP_CHKSUM
HARDWARE
21
ICP prom checksum.
FATAL_ADI_NOACK
HARDWARE
30
ADI did not respond to command.
FATAL_ADI_QUNDERFLOW
HARDWARE
31
ADI Rx circular queue underflowed.
FATAL_LCD_NOACK
HARDWARE
40
LCD did not acknowledge message.
FATAL_LCD_HARD_FAIL
HARDWARE
41
LCD hardware is invalid.
FATAL_SCI_NOHEAP
HARDWARE
50
Serial communication interface out of heap (RAM memory) space.
FATAL_ICP_NOACK
HARDWARE
60
ICP did not acknowledge message.
FATAL_EXTIO_ICPFAIL
HARDWARE
70
ICP failed in a fork.
FATAL_RADIO_ASPWRT
HARDWARE
80
Radio driver could not write to ASP.
FATAL_ROM_NOHEAP
HARDWARE
90
Software memory error - ROM task.
FATAL_BL_NOHEAP
HARDWARE
91
Software memory error - Boot loader.
FATAL_BL_SCI_ATACH
HARDWARE
92
Boot loader could not attach to SCI.
Operational Software Non-Fatal System Errors
ERROR NAME
MESSAGE
CODE
DESCRIPTION
PIFEAT_SNR_ERROR
FEAT ERR
550
Feature encryption - Can not read radio ROM serial number.
PIFEAT_READ_ERROR
FEAT ERR
551
Personality feature encryption read failure or data not available.
PIFEAT_CRC_ERROR
FEAT ERR
552
Decryption failure. Personality feature encryption CRC failure.
RI_DSPDOWN_NOATTEMPT
DSP ERR
850
DSP not found
AEGIS_ADIDOWN_
NOTFOUND
DSP ERR
851
DSP file not found.
AEGIS_ADIDOWN_CRCFAIL
DSP ERR
852
DSP file not found.
AEGIS_ADIDOWN_ENCERR
DSP ERR
853
Radio feature encryption does not match DSP file.
AEGIS_ADIDOWN_PMFAIL
DSP ERR
854
DSP file is corrupted or hardware failure. RE-program radio or power cycle the
radio.
AEGIS_ADIDOWN_DMFAIL
DSP ERE
855
DSP file is corrupted or hardware failure. Re-program radio or power cycle radio.
AEGIS_ADIDOWN_BIOSERR
DSP ERR
856
Hardware failure.
AEGIS_KEYLOAD_
NOBANKS
DSP ERR
860
Personality did not assign banks for the keys.
AEGIS_PVT_NONE
FEAT ERR
870
Private is not feature encrypted.