Electrical connection – Electrolux C67600K User Manual
Page 38
 
78
Electrical Connection
Before connecting, check that the nominal voltage of the appliance, 
that is the voltage stated on the rating plate, corresponds to the avail-
able supply voltage. The rating plate is located on the lower casing of 
the hob.
The heating element voltage is AC230V~. The appliance also works 
perfectly on older networks with AC220V~.
The hob is to be connected to the mains using a device that allows the 
appliance to be disconnected from the mains at all poles with a contact 
opening width of at least 3 mm, eg. automatic line protecting cut-
out,earth leakage tripsorfuse.
A type H05VV-F cable or one with a higher grade must be used as the 
mains connecting cable.
The connection must be carried out as shown in the diagram. The con-
necting links should be fitted according to the appropriate connection 
diagram. The earth lead is connected to terminal 
E. The earth lead
must be longer than leads carrying electric current.
The cable connections must be made in accordance with regula-
tions and the terminal screws tightened securely.
Finally, the connecting cable is to be secured with the mains cable cleat 
and the covering closed by pressing firmly (lock into place).
Before switching on for the first time, any protective foil or stickers 
must be removed from the glass ceramic surface.
1
Once connected to the mains supply check that all cooking zones are 
ready for use by briefly switching each on in turn at the maximum set-
ting.