Ordering information, Absolute maximum ratings, Electrical specifications – Linx Technologies LICAL-TRC-MT User Manual

Page 4: Electrical specifications ordering information

Advertising
background image

2

3

MT Series Transcoder Specifications

Parameter

Symbol

Min.

Typ.

Max.

Units Notes

Power Supply

Operating Voltage

V

CC

2.0

5.5

VDC

Supply Current

l

CC

At 2.0V V

CC

340

450

µA

1

At 3.0V V

CC

500

700

µA

1

At 5.0V V

CC

800

1,200

µA

1

Power Down Current

l

PDN

At 2.0V V

CC

0.15

1.2

µA

At 3.0V V

CC

0.20

1.5

µA

At 5.0V V

CC

0.35

1.8

µA

Transcoder Section

Input Low

V

IL

0.0

0.2 x V

CC

V

2

Input High

V

IH

0.8 x V

CC

V

CC

V

3

Output Low

V

OL

0.6

V

Output High

V

OH

V

CC

– 0.7

V

Input Sink Current

25

mA

Output Drive Current

25

mA

Environmental

Operating Temperature Range

–40

+85

°C

1. Current consumption with no active loads.
2. For 3V supply, (0.2 x 3.0) = 0.6V max.
3. For 3V supply, (0.8 x 3.0) = 2.4V min.

Electrical Specifications

Ordering Information

Ordering Information

Part Number

Description

LICAL-TRC-MT

MT Transcoder

MDEV-LICAL-MT

MT Master Development System

MT transcoders are shipped in reels of 1,600

Absolute Maximum Ratings

Figure 2: Ordering Information

Figure 3: Absolute Maximum Ratings

Absolute Maximum Ratings

Supply Voltage V

CC

−0.3

to

+6.5

VDC

Any Input or Output Pin

−0.3

to

V

CC

+ 0.3

VDC

Max. Current Sourced by Output Pins

25

mA

Max. Current Sunk by Input Pins

25

mA

Max. Current Into V

CC

250

mA

Max. Current Out Of GND

300

mA

Operating Temperature

−40

to

+85

ºC

Storage Temperature

−65

to

+150

ºC

Exceeding any of the limits of this section may lead to permanent damage to the device.
Furthermore, extended operation at these maximum ratings may reduce the life of this
device.

Warning:

This product incorporates numerous static-sensitive

components. Always wear an ESD wrist strap and observe proper ESD
handling procedures when working with this device. Failure to observe
this precaution may result in module damage or failure.

Figure 4: Electrical Specifications

Advertising