Operating instructions – Enviro MAX 50-1531 User Manual

Page 8

Advertising
background image

Operating Instructions

O

PERATING

Y

OUR

P

ELLET

S

TOVE

:

DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN. Keep hopper lid closed

except during re-fuelling.
CAUTION:
When operating during adverse weather, such as high winds or freezing rain, if the unit

exhibits dramatic changes in combustion stop using the unit immediately. Watch for blocked exhaust

outlet.
PRE-BURN CHECK: The burn pot liner holes must be clear and the liner installed properly against the

ignitor tube. Check the hopper for enough pellets to start the unit.
Note:
The thermostat mode can be changed during normal operation.

Figure 3: Thermostat Switch in

MANUAL position.

Figure 4: Thermostat Switch in

HIGH/LOW position.

Figure 5: Thermostat Switch in

AUTO/OFF position.

6

7

8

1

2

3

4

5

MANUAL MODE:
All control of circuit board function is adjusted at the circuit board.
To START: Press the ON / OFF button. The stove will turn on.

The system light will flash. The Auger Light will flash with each pulse

of the auger (the Auger Feed Rate is pre-programmed during start-

up). The Heat Level Indicator will show the Heat Level that the stove

will run at after start-up.
If this is the first time the unit has been started or the unit has run

out of fuel, the auger will need to be primed. Press the Manual Auger Feed button until fuel starts to drop

into the Burn Pot Liner (see “O

PERATING

I

NSTRUCTIONS

; C

ONTROL

B

OARD

F

UNCTIONS

”).

When a fire has been established, the System Light will turn solid and the convection blower will turn on

(after approximately 10 - 15 minutes), and the Auger Light will continue to flash to the corresponding

Heat Level setting.
To OPERATE: Press the Heat Level button to change the desired Heat Level Output setting.
The speed of the convection blower is controlled by the setting of the heat level. The Convection Blower

does not operate when on Heat Output is on LOW, this is to prevent over cooling of the unit.
When operating on LOW HEAT LEVEL, the feed rate can be adjusted, using the auger trim, for different

quality fuels. These settings can be used if the fire keeps going out on low (poor quality fuel) or if the low

setting is too hot for the room (see “O

PERATING

I

NSTRUCTIONS

; C

ONTROL

B

OARD

F

UNCTIONS

”).

HIGH/LOW MODE: (Requires a Thermostat or Timer)
INITIAL START-UP: See MANUAL MODE above.
OPERATION: When the thermostat calls for heat (contacts are

closed) the stove settings are adjustable as per Manual Mode. When

the thermostat contacts open, the HEAT LEVEL and Fans will drop

down to the LOW setting until the thermostat contacts close again.

*The LOW heat setting can be adjusted for different fuel qualities

(see “O

PERATING

I

NSTRUCTIONS

- C

ONTROL

B

OARD

F

UNCTIONS

”). The stove will

come back to the previous HEAT LEVEL setting when the thermostat

contacts close again.
AUTO/OFF MODE: (Requires a Thermostat or Timer)
INITIAL START-UP: See MANUAL MODE above.
OPERATION: When the thermostat contacts close, the unit will

light automatically. Once up to temperature, the stove operates the

same as in MANUAL. When the thermostat contacts open, the stove’s

6

7

8

1

2

3

4

5

6

7

8

1

2

3

4

5

8