Troubleshooting guide

Fault

Cause

Remedy

Engine does not start

Automatic oil cut-out has not
responded

Spark plug fouled

No fuel

Check oil level, top up engine
oil

Clean or replace spark plug
(electrode spacing 0.6 mm)

Refuel / have the petrol cock
checked

Generator has too little or no
voltage

Controller or capacitor
defective

Overcurrent circuit-breaker has
triggered

Air filter dirty

Contact your dealer

Actuate the circuit-breaker and
reduce the consumers

Clean or replace the filter