INSTALLING OPTIONAL BLOWER VFS-BK

1. Lower bottom louver.

2. Remove screen front by lifting upward on screen front.

3. Remove top louver [(2) 8 x 1/2" Phillips screws].

4. Remove rear log support from inner casing [three (3) 10 x 1/2"

screws.] (See Figure 1)

5. Remove three (3) 10 x 1/2" screws that attach burner assembly

to inner bottom. (See Figure 1)

6. Remove six (6) 10 x 1/2" screws that attach inner casing to

outer casing. Loosen two (2) 10 x 1/2" screws at interior, top

of inner casing. Remove inner casing from outer casing by

pivoting left side of inner casing. (See Figure 1)

Figure 1

7. For fireplace that is not installed, remove burner assembly

from interior of fireplace.

7. For fireplace that is installed, burner assembly will remain

with fireplace.

8. Insert blower assembly into left side of outer casing. Motor

with wiring will be to inside of outer casing, blower chute will

be facing upward. (See Figure 2)

9. Place and align two (2) orange motor mounting gaskets at rear

of motor mounting brackets. Start two (2) 8 x 1/2" Phillips

screws into motor mounting brackets and gaskets on side

opposite motor. Start one (1) 8 x 1/2" Phillips screw into top

motor mounting bracket and gasket adjacent to motor. Align

and attach blower assembly to outer casing side. (See Figure

2)

10. Snap Heyco into blower shield side.

11. Place blower shield side adjacent to motor. Route blower motor

wires through Heyco on blower shield side. (See Figure 3 and

Figure 4)

VFS-BK for Unvented Gas Fireplace Model VF24FP2-1, VF24FP3-1

12. Attach black wire from wire harness to OFF terminal on

AUTO/OFF/ON switch.

13. Attach white/black wire from wire harness to ON terminal on

AUTO/OFF/ON switch.

14. Attach black/red wire from wire harness to AUTO terminal

on AUTO/OFF/ON switch.

Figure 2

15. Route two (2) flag terminals on wire harness through Heyco

on blower shield side.

16. Attach two (2) flag terminals on wire harness to fan control

(bracket).

17. Route cord set wires through access hole on right side of outer

casing.

18. Insert strain relief in access hole on right side of outer

casing.

19. Attach (1) pin terminal from black (hot) wire, smooth insulation

on cord set to (1) socket terminal from black wire on AUTO/

OFF/ON switch.

20. Attach (1) pin terminal from black (neutral) wire, ribbed

insulation on cord set to (1) socket terminal from black wire

on motor.

21. Attach (1) pin terminal from white wire on AUTO/OFF/ON

switch to (1) socket terminal from white wire on motor.

22. Attach green ground wires from wiring harness and cord set

to interior back of outer casing with one (1) 8 x 1/2" Phillips

screw.