Transportation and Handling

The POWER SPOT 700 II™ comes with two carrying handles built into the base. Always

transport the fixture by these handles. Never lift or carry the POWER SPOT 700 II™ by the

yoke (head assembly) this can seriously damage the unit and will void your manufactures

warranty.

Connections

Power supply:

Electronic ballast with:

90~260 Volts, 50~60 Hz,

Grounded contact type plug – Neutrik Powercon

Connected load 1000W <=> 4.5 A (blind current compensation).

NOTE: The universal power supply will accept any voltage source as detailed above
without any type of internal or user modifications.

DMX:

USITT DMX 512 Standard input/output, 3 pole connectors.

[+] = Pin 3 / [-] = Pin 2 / [Ground] = Pin 1

Fuse Requirements:

The POWER SPOT 700 II’s electronic and lamp systems are protected by two GMA
(5x20mm) external fuses:

Lamp: 250v/10A (120v Operation) or 250v/5A (220v Operation)

Electronics: 250v/2A (120v Operation) or 250v/1A (220v Operation)

The fuse requirements are clearly printed on the side of the fixture.

• Always disconnect main power before changing the fuse!

• Always replace with the exact same type fuse unless otherwise specified by

an authorized Elation® service technician. Replacing with anything other than
the specified fuse can severely damage your fixture and will void your
manufactures warranty.