Filter cont. fan timer – Curtis RDH705 User Manual

Page 4

Advertising
background image

4

5

CONTROL PADS ON THE DEHUMIDIFIER

Control pads

3

When you push the button to change
operation modes, the unit will make
a beep sound to indicate that it is
changing modes.

NOTE: The control panel of the unit you purchased may be slightly different according to the
models.

Fig.1

Fan Pad

Control the fan speed. Press to select either High
or Normal fan speed. Set the fan control to High for
maximum moisture removal. When the humidity has
been reduced and quiet operation is preferred, set
the fan control to Normal.

2

Filter Pad

The check filter feature is a reminder to clean the
Air Filter for more efficient operation. The Filter
light(Clean filter l ight) will illuminate after 250 hours
of operation. To reset after cleaning the filter, press
the Filter pad and the light will go off.

5

Humidity Set Control Pads

7

: Down/Up Pads

TIMER Set Control Pads

Use the Up/Down pads to set the Auto
start and Auto stop time from 0.0 to 24.

The humidity level can be set within a range of
35%RH(Relative Humidity) to 85%RH(Relative
Humidity) in 5% increments.
For drier air, press the pad and set to a lower
percent value(%).
For damper air, press the pad and set a higher
percent value(%).

CONTROL PADS ON THE DEHUMIDIFIER

Other features

Bucket Full Light

Glows when the bucket is ready to be
emptied, or when the bucket is removed
or not replaced in the proper position.

When frost builds up on the evaporator coils, the
compressor will cycle off and the fan will continue
to run until the frost disappears.

Auto Defrost

Wait 3 minutes before resuming operation

After the unit has stopped, it can not be restart
opertation in the first 3 minutes. This is to protect
the unit. Operation will automatically start after
3 minutes.

Setting the Timer

When the unit is on, first press the Timer
button, the Timer Off indicator light
illuminates. It indicates the Auto Stop
program is initiated. Press it again the
Time On indecator light illuminates.It
indicates the Auto Start is initiated.
When the unit is off, first press the Timer
button, the TIMER ON indicator light
illuminates. It indicates the Auto Start
program is initiated. Press it again the
Time Off indecator light illuminates.It
indicates the Auto Stop is initiated.
Press or hold the UP or DOWN pad to
change the Auto time by 0.5 hour incre-
ments, up to 10 hours, then at 1 hour
increments up to 24 hours. The control
will count down the time remaining until
start.
The selected time will register in 5 seconds
and the system will automatically revert
back to display the previous humidity
setting.
When the Auto start & Auto stop times are
set, within the same program sequence,
TIMER ON OFF indicator lights illuminate
identifying both ON and OFF times are
now programmed.
Turning the unit ON or OFF at any time or
adjusting the timer setting to 0.0 will cancel
the Auto Start/Stop function.
When LED display window displays the
code of P2, the Auto Start/Stop function
will also be cancelled.

Check filter feature

The system starts to count the time once the fan
motor operates. The check filter feature can be
only activated when the accumulated operation
time achieves 250 hours or more. The Reset
light(Clean filter indicator light) flashes at one time
per second, after finishing clean the air filter, press
the Filter pad and the Reset light(Clean filter indicator
light) goes off.

10

Display

Shows the set % humidity level from 35% to 85% or auto
start/stop time (0~24) while setting, then shows the actual
( ± 5% accuracy) room % humidity level in a range of
RH(Relative Humidity) to 90%RH(Relative Humidity).
Error Codes and Protection Code:
AS
- Humidity sensor error--Unplug the unit and plug it back
in. If error repeats, call for service.
ES- Temperature sensor error-- Unplug the unit and plug it
back in. If error repeats, call for service.
P2- Bucket is full or bucket is not in right position-- Empty
the bucket and replace it in the right position.

30%

6

Timer Pad

Press to initiate the Auto start and Auto stop feature,
in conjuction with the and key pads.

Auto Shut Off

The

shuts off after 30 seconds when

the bucket is full, or when the bucket is removed
or not replaced in the proper position.When the
setting humidity is reached, the unit will be shut
off automatically. For some models,the fan motor
will continue operating.

dehumidifier

Auto-Restart
If the unit breaks off unexpectedly due to the power cut,
it will restart with the previous function setting automa-
tically when the power resumes.

3

Low fan
indicator light

Auto defrost operation on
indicator light

High fan
indicator light

Filter

Cont.

Fan

Timer

Filter

Full

Cont.

On

Off

Turbo

Normal

Auto defrost

1

2

4

5

6

7

Clean filter
indicator light

Bucket full
indicator light

Continuous
operation on
indicator light

Timer on/off
indicator light

1

Continue Pad

Press to activate the continuous dehumidifying
operation.

4

Power Pad

Press to turn the dehumidifier on and off.

EC- Unit malfuction--




for

Please make sure whether the

enviroment temperature is suitable for the stated
temperature in the manual or not.If not,please operate
the unit under the stated temperature.If the enviroment
temperature is suitable for the stated temperature,please
call service.

Advertising
This manual is related to the following products: