Installation, 5” x 8” rigid pipe cross reference chart (cont.) – CarAlarms.com P90-NG1 User Manual

Page 16

Advertising
background image

Excalibur

®

P90 Zero Clearance Direct Vent Gas Fireplace

16

FPI

946-604/P

Simpson Direct Vent Vent Guard (Optional)

946-623/P

AstroCap XL Horizontal Cap

770-994

Rigid Pipe Adapter (Must use with all Rigid Piping)

946-506/P

Vent Guard (Optional)

946-625

Vinyl Siding Standoff - AstroCap XL

Description

Simpson

Direct Vent Pro

®

Simpson

Direct Vent GS

®

Discontinued

Selkirk

Direct-Temp™

Metal-Fab

®

Sure Seal

Round Support / Radiation Sheild

N/A

N/A

N/A

N/A

Flat Flashing

N/A

N/A

N/A

N/A

Attic Insulation Shield 12”

58DVA-IS - N/A from FPI

58DVA-IS - N/A from FPI

N/A

N/A

Basic Horizontal Termination Kit (A)

N/A

N/A

5DT-HKA

N/A

Horizontal Termination Kit (B)

58DVA-KHA

N/A

5DT-HKB

N/A

Vertical Termination Kit

58DVA-VCH

1291

5DT-VKC

N/A

High Wind Vertical Cap

N/A

N/A

N/A

N/A

High Wind Horizontal Cap

DISC.

1285

N/A

N/A

Horizontal Square Termination Cap

N/A

1284

5DT-HHC

5DHT

Vertical Termination Cap

N/A

N/A

5DT-HVC

5DVT

Storm Collar

58DVA-SC

1253

5DT-SC

5DSC

Adjustable Flashing, 0/12-6/12

58DVA-F6

1243

5DT-AF6

5DF

Adjustable Flashing, 6/12-12/12

58DVA-F12

1243S

5DT-AF12

5DF-12

Vinyl Siding Standoff

58DVA-VSS

1250

5DT-VS

5DVS

Vinyl Siding Shield Plate

N/A

N/A

5DT-VSP

N/A

Snorkel Termination 14”

58DVA-SNK14

1282

5DT-ST14

5DST14

Snorkel Termination 36”

N/A

1281

5DT-ST36

5DST36

Restrictor Disk

58DVA-RD

N/A

N/A

N/A

Colinear Flex Liner Adapter (3” Ø)

N/A

N/A

N/A

N/A

5” x 8” Rigid Pipe Cross Reference Chart (Cont.)

Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.

*NOTE: When using Metal-Fab Sure Seal Rigid Piping please note that either the Adaptor (5DDA) or 90º Starter Elbow

(5D90A) must be used in conjunction with FPI Rigid Pipe Adaptor (770-994).

NOTE: Horizontal runs of vent must be level, or have a 1/4 inch rise for every 1 foot of run towards
the termination. Never allow the vent to run downward. This could cause high temperatures and
may present a possible fi re hazard.

Offset Pipe Selection:
Use this table to determine offset pipe lengths.

Pipe Length

5” x 8” Venting

Run (X)

Rise (Y)

0”(0mm)

5-11/16”(144mm)

15-5/16”(389mm)

6”(152mm)

8-13/16”(224mm)

18-7/16”(468mm)

9”(229mm)

10-15/16”(278mm)

20-9/16”(522mm)

12”(305mm)

13”(330mm)

22-11/16”(576mm)

24”(610mm)

21-7/16”(697mm)

31-1/16”(789mm)

36”(914mm)

29-13/16”(757mm)

39-7/16”(1002mm)

48”(1219mm)

38-1/4”(972mm)

47-7/8”(1216mm)

L

Y

X

For specifi c instructions or details on particular
venting components please visit the following
websites:

Simpson Direct Vent Pro: www.duravent.com

Selkirk Direct-Temp: www.selkirkcorp.com

Metal-Fab Sure Seal: www.mtlfab.com

INSTALLATION